Mokon Hydrotherm II Plus
 
Pump Flow Rate & Pressure Heating Capacity*
Process
Connection
Supply/Drain
Connection
Dimensions
L x W x H
1/2 hp 15 gpm up to 15 PSI 3, 6, 9, or 12 kW 1.25" NPT 1/2" NPT 27.5" x 11" x 24.5"
3/4 hp 25 gpm up to 26 PSI 3, 6, 9, or 12 kW 1.25" NPT 1/2" NPT 27.5" x 11" x 24.5"
1 hp 30 gpm up to 32 PSI 3, 6, 9, or 12 kW 1.25" NPT 1/2" NPT 27.5" x 11" x 24.5"
1-1/2 hp 40 gpm up to 32 PSI 3, 6, 9, or 12 kW 1.25" NPT 1/2" NPT 27.5" x 11" x 24.5"
2 hp 50 gpm up to 32 PSI 3, 6, 9, or 12 kW 1.25" NPT 1/2" NPT 27.5" x 11" x 24.5"
3 hp 60 gpm up to 34 PSI 3, 6, 9, or 12 kW 1.25" NPT 1/2" NPT 27.5" x 11" x 24.5"

* Variety of voltages and additional wattages are available; consult factory for more information
 

Hydrotherm Internal View

 
Constructed of all non-ferrous plumbing and heating components, as well as a unique stainless steel pump and high efficiency heating design, the Hydrotherm II Plus is built for lasting performance. With a footprint of approximately 2 square feet, the system is an easy addition anywhere in your manufacturing process.

A. Hybrid-epoxy powder coated cabinetry
(14 ga. base/16 ga. electrical enclosure)
B. Microprocessor-based controller in easily accessible control panel
C. Suction and discharge pressure gauges
D. High temperature safety shut-off switch
E. Pressure relief valve
F. Horizontal stainless steel heater canister
G. Copper heating elements mounted in back of canister for easy tool access
H. Low pressure safety shut-off switch
I.  Solenoid cooling valve
J. Stainless steel pump
K. Casters for easy portability
Eurotherm Controller
Eurotherm 3216 Series

The Eurotherm 1/16 DIN (3216) microprocessor controller is now standard on the entire line of portable chillers, water and heat transfer fluid temperature control systems. This controller is operator friendly and easy-to-use. Standard features include a microprocessor PID controller for the highest accuracy in temperature control, a dual LCD display that shows set point and actual fluid temperature, and advanced PID overshoot protection with self-tuning capabilities for increased accuracy. Scrolling text messages deliver plain language messages to let users know exactly what is happening to the process.

There are optional 1/8 or 1/4 DIN controllers available, with high/low deviation alarm, remote set point and retransmission and serial communication. A five-year warranty comes standard with the controller.